Print

Useful HMI reserved and special registers

 

Use your browser’s search [Ctrl] [F] to find the keyword

 

LBxxxxx = BIT

LWxxxxx = WORD

See HMI register types: LB, LW, RWI and retentive/save register

LBxxxxx

LB6xxxx Concerns Description Read/Write
LB60000 LB60099 Initialization Settings ON Enable the initialization ON when system starts R/W
LB60100 Download Formula/Recipe Write the data of this RWI to device if it is triggered; reset after execution R/W
LB60101 Upload Formula/Recipe/Recipe Read the Formula/Recipe data of device to RWI register if it is triggered; reset after execution R/W
LB60102 Preserve Formula/Recipe Write Formula/Recipe from RWI to FLASH if it is triggered; reset after execution R/W
LB60103 Formula/Recipe Downloading Indication ON if Formula/Recipe is being written to device; OFF after the end of downloading R
LB60104 Formula/Recipe Uploading Indication ON if Formula/Recipe is being read to device; OFF after the end of uploading R
LB60105 Restart HMI Restart system if it is triggered R
LB60106 Backlight Control Close Backlight when it is ON; Open Backlight when it is OFF R/W
LB60107 Communication State of COM1 ON means normal communication; OFF means communication failure or no communication R
LB60108 Communication State of COM2 ON means normal communication; OFF means communication failure or no communication R
LB60109 Modification preservation of COM1 communication parameters Write modified communication parameters to FLASH if it is triggered; OFF after execution R/W
LB60110 Modification preservation of COM2 communication parameters Write modified communication parameters to FLASH if it is triggered; OFF after execution R/W
LB60111 Modification confirmation of system parameters Write modified communication parameters to FLASH if it is triggered; OFF after execution R/W
LB60112 Abnormal communication window (Comm Error) ON means permission of exception window popping up; OFF means prohibition R/W
LB60113 Mouse cursor control ON means disolay of mouse censor; OFF means prohibition (Only available for touch) R/W
LB60114 Connection state of USB ON means with USB device connection; OFF means no connected USB device R
LB60115 Coonection state of SD card ON means with SD card connection; OFF means no connected SD card R
LB60116 Touch Sound Whether enable sound when touch or mouse click R/W
LB60117 Alarm Sound Whether enable alarm sound when alarm occurs R/W
LB60118 Clear historical alarm record Clear historical alarm record (Reset automatically) R/W
LB60119 Clear operation record Clear operation record (Reset automatically) R/W
LB60120 Clear historical data Clear historical data (Reset automatically) R/W
LB60121 Reload Formula/Recipe Reload the Formula/Recipe data of the current one while it is ON; OFF when the reloading ends R/W
LB60123 Save historical alarm Save historical alarm record to disk when it is ON; OFF after the preservation R/W
LB60124 Save historical data Save historical data to disk when it is ON; OFF after the preservation R/W
LB60125 Send historical alarm file to SD card Send historical alarm file to SD card; OFF automatically after the sending R/W
LB60126 Send historical data file to SD card Send historical data file to SD card; OFF automatically after the sending R/W
LB60127 Send historical alarm file to U disk Send historical alarm file to U disk; OFF automatically after the sending R/W
LB60128 Send historical data file to U disk Send historical data file to U disk; OFF automatically after the sending R/W
LB60129 Send the current project to U disk Send the current project to U disk; OFF automatically after the sending R/W
LB60130 Send the current project to SD card Send the current project to SD card; OFF automatically after the sending R/W
LB60133 User Logout Cancel User Login when it is ON; Reset automatically after the cancelation R/W
LB60141 Whether there is a real-time alarm ON when a real-time alarm occurs R
LB60142 Screen saver state of system ON when it is under screen saver stat R/W
LB60143 Copy operation record to U disk Send operation record to U disk in case of ON; OFF automatically after the sending R/W
LB60144 Copy operation record to SD card Send operation record to SD card in case of ON; OFF automatically after the sending R/W
LB60145 Copy all Formula/Recipes to U disk Send Formula/Recipes to U disk in case of ON; OFF automatically after the sending W
LB60146 Copy Formula/Recipes to SD card Send Formula/Recipe files to SD card incase of ON; OFF automatically after the sending W
LB60147 End mark of Qrcode scanning USB Triggered in case of ON R/W
LB60148 Import historical trigger bit from U disk Triggered in case of ON; reset automatically. Historical data file must be histdata.csv; otherwise the execution is invalid. R/W
LB60149 Import historical trigger bit from SD card Triggered in case of ON; reset automatically R/W
LB60150 Export specific ID Formula/Recipe to U disk trigger bit Triggered in case of ON; reset automatically R/W
LB60151 Export specific ID Formula/Recipe to SD card trigger bit Triggered in case of ON; reset automatically R/W
LB60152 Export specific ID Formula/Recipe from U disk to HMI trigger bit Triggered in case of ON; reset automatically R/W
LB60153 Export specific ID Formula/Recipe from SD card to HMI trigger bit Triggered in case of ON; reset automatically R/W
LB60154 Clear trigger bit of specific ID Formula/Recipe trigger bit Triggered in case of ON; reset automatically R/W
LB60155 Cover Formula/Recipe trigger bit Triggered in case of ON; reset automatically R/W
LB60156 Read Formula/Recipe and save trigger bit Triggered in case of ON; reset automatically R/W
LB60163 Export Formula/Recipes to U disk by groups R/W
LB60164 Export Formula/Recipes to SD card by groups R/W
LB60165 Ethernet communication 1=Normal, 0=Error R
LB60167 Usb test function HMI will scan the touchscreen usb disk for the use of the CVS file for the import and export of the recipe
LB60168 The historical data is exported to USB Disk Triggered in case of ON; reset automatically
LB60169 Automatic disable function of station number When using multi-slave «Extended» mode communication, automatically disables or re-enables the faulty station(s)
LB60173 Restart the VNC server Restart the VNC server R/W

LWxxxxx

LW Concerns Description Read/Write
LW44000 LW44003 Current IP address used Allow to know the current IP address used for the communication to PLC R
LW59010 LW59025 Stop or Run the communication with Slave ID Each address corresponds to 16 stations/ID slaves on COM1 in RS485 extended mode. R/W
LW59026 LW59041 Stop or Run the communication with Slave ID Each address corresponds to 16 stations/ID slaves on COM2 in RS485 extended mode. R/W
LW59042 LW59057 Stop or Run the communication with Slave ID Each address corresponds to 16 stations/ID slaves on ETHERNET in RS485 extended mode. R/W
LW59058 LW59073 Station number communication status COM1 Corresponding to station number from 0-255, each address corresponds to 16 station numbers. For example, 59058 means station number 0-15, and so on.The X bit is 1 = Communication error with station R
LW59074 LW59089 Station number communication status COM2 Corresponding to station number from 0-255, each address corresponds to 16 station numbers. For example, 59074 means station number 0-15, and so on.The X bit is 1 = Communication error with station R
LW59090 LW59105 Station number communication status Ethernet Corresponding to station number from 0-255, each address corresponds to 16 station numbers. For example, 59090 means station number 0-15, and so on.The X bit is 1 = Communication error with station R
LW60000 Local time: second Bcd code; effective value range: 0-59 R/W
LW60001 Local time: minute Bcd code; effective value range: 0-59 R/W
LW60002 Local time: hour Bcd code; effective value range: 0-23 R/W
LW60003 Local time: day Bcd code; effective value range: 1-31 R/W
LW60004 Local time: month Bcd code; effective value range: 1-12 R/W
LW60005 Local time: year Bcd code; effective value range: 0-9999 R/W
LW60006 Local time: week Bcd code; effective value range: 1-7 R
LW60007 System running hours Hours of system running time R
LW60008 System running minutes Minutes of system running time R
LW60009 System running seconds Seconds of system running time R
LW60010 Serial number of the current screen window Serial number of the current screen R
LW60012 Current language Corresponding language serial number R
LW60013 Upper limit of value input Upper limit of allowable input in user-defined keyboard; ASC display R
LW60023 Lower limit of value input Lower limit of allowable input in user-defined keyboard; ASC display R
LW60033 Data contents shown in keyboard Data contents shown in keyboard; characters entered via keyboard; ASC display R
LW60065 Current Logged in User Current user serial number R
LW60066 Current Logged in User Password Display the current user password; 16 characters; ASC display R
LW60074 Current logged in User name Display the current user name; 32 characters; ASC display R
LW60090 Whether enable User 1 0-inactivate; 1-activate R
LW60091 Whether enable User 2 0-inactivate; 1-activate R
LW60092 Whether enable User 3 0-inactivate; 1-activate R
LW60093 Whether enable User 4 0-inactivate; 1-activate R
LW60094 Whether enable User 5 0-inactivate; 1-activatev R
LW60095 Whether enable User 6 0-inactivate; 1-activate R
LW60096 Whether enable User 7 0-inactivate; 1-activate R
LW60097 Whether enable User 8 0-inactivate; 1-activate R
LW60098 Name of User 1 32 characters; ASC display R
LW60114 Name of User 2 32 characters; ASC display R
LW60130 Name of User 3 32 characters; ASC display R
LW60146 Name of User 4 32 characters; ASC display R
LW60162 Name of User 5 32 characters; ASC display R
LW60178 Name of User 6 32 characters; ASC display R
LW60194 Name of User 7 32 characters; ASC display R
LW60210 Name of User 8 32 characters; ASC display R
LW60226 Password of User 1 16 characters; ASC display R
LW60234 Password of User 2 16 characters; ASC display R
LW60242 Password of User 3 16 characters; ASC display R
LW60250 Password of User 4 16 characters; ASC display R
LW60258 Password of User 5 16 characters; ASC display R
LW60266 Password of User 6 16 characters; ASC display R
LW60274 Password of User 7 16 characters; ASC display R
LW60282 Password of User 8 16 characters; ASC display R
LW60290 Screen saver time Displays the specific screen saver time; setting range: 0-60. Can be used to wake up the HMI screen saver by the PLC: Set it to 0 and then to any value from 0 to 60. R/W
LW60291 Flicker circle of Indicator light Flicker circle of Indicator light; the minimum value is 0.1s R/W
LW60292 X position in case of touch Position of X coordinate in case of touch R
LW60293 Y position in case of touch Position of Y coordinate in case of touch R
LW60294 X position at the end of touch Position of X coordinate at the end of touch R
LW60295 Y position at the end of touch Position of Y coordinate at the end of touch R
LW60296 Touch state 1-Touch; 0-Release R
LW60297 Checking of COM1 Communication parameters, checking: 0-NONE, 1-EVEN, 2-ODD R/W
LW60298 Baud rate of COM1 Communication parameters, baud rate: 0-1200,1-2400,2-4800,3-9600,4-19200,5-38400,6-57600,7-115200 R/W
LW60299 Stop Bit of COM1 Communication parameters, stop bit: 0-1stops,1-2stops R/W
LW60300 Data Length of COM1 Communication parameters, data length: 0-7bits; 1-8bits R/W
LW60301 HMI Address of COM1 Communication parameters, HMI address R/W
LW60302 PLC Address of COM1 Communication parameters, PLC address R/W
LW60303 Continuous address interval of PLC to COM1 The maximum length of contiguous address that can be read by a single communication R/W
LW60304 Communication time of COM1 Delay time of communication R/W
LW60305 Retry number of COM1 Number of retries in case of abnormal system R/W
LW60306 Address Mode of COM1 Address mode: 0-standard mode; 1-extended mode R
LW60307 Time of COM1 timeout Set communication timeout; unit: ms R/W
LW60308 Current waiting time of COM1 communication Current waiting time of communication; unit : ms R/W
LW60309 HMI Site of COM1 0-Machine; 1-Far-end R/W
LW60312 Checking of COM2 Communication parameters, checking: 0-NONE, 1-EVEN, 2-ODD R/W
LW60313 Baud rate of COM2 Communication parameters, baud rate: 0-1200,1-2400,2-4800,3-9600,4-19200,5-38400,6-57600,7-115200 R/W
LW60314 Stop Bit of COM2 Communication parameters, stop bit: 0-1stops,1-2stops R/W
LW60315 Data Length of COM2 Communication parameters, data length: 0-7bits; 1-8bits R/W
LW60316 HMI Address of COM2 Communication parameters, HMI address R/W
LW60317 PLC Address of COM2 Communication parameters, PLC address R/W
LW60318 Continuous address interval of PLC to COM2 The maximum length of contiguous address that can be read by a single communication R/W
LW60319 Communication time of COM2 Communication delay time R/W
LW60320 Retry number of COM2 Number of retries in case of abnormal system R/W
LW60321 Address Mode of COM2 Address mode: 0-standard mode; 1-extended mode R
LW60322 Time of COM2 timeout Set communication timeout; unit: ms R/W
LW60323 Current waiting time of COM2 communication Current waiting time of communication; unit : ms R/W
LW60324 HMI Site of COM2 0-Machine; 1-Far-end R/W
LW60327 Number of historical alarm Sum of recorded historical alarm. Double Word R
LW60329 Number of historical data Sum of recorded historical data. Double Word R
LW60333 Keyboard Language Switch 1-Chinese keyboard, 0-English keyboard; aim at standard keyboard R/W
LW60334 CPU usage Current CPU usage rate during the running of system R
LW60335 Backlight luminance value Backlight luminance value Value from 140 to 450 R/W
LW60337 Creation time of the current project: year Creation time of the current project: year R
LW60338 Creation time of the current project: month Creation time of the current project: month R
LW60339 Creation time of the current project: day Creation time of the current project: day R
LW60340 Current language Set current language W
LW60359 Copy historical alarm Copy historical alarm between specific serial number range to U disk when the value is 1 R/W
LW60360 Copy historical alarm Copy historical alarm between specific serial number range to SD card when the value is 1 R/W
LW60361 Copy historical alarm Copy historical alarm between specific time range to U disk when the value is 1 R/W
LW60362 Copy historical alarm Copy historical alarm between specific time range to SD card when the value is 1 R/W
LW60363 Export the start serial number of historical alarm Export the start serial number of historical alarm R/W
LW60365 Export the end serial number of historical alarm Export the end serial number of historical alarm R/W
LW60367 Export start time of historical alarm Length: six characters; year, month, day, hour, minute and second R/W
LW60373 Export end time of historical alarm Length: six characters; year, month, day, hour, minute and second R/W
LW60379 File name of historical alarm exported to U disk and SD card Length: 24 characters R/W
LW60408 Historical data Current group number of historical data imported or exported R/W
LW60409 Historical data Copy historical data between specific serial number range to U disk when the value is 1 R/W
LW60410 Historical data Copy historical data between specific serial number range to SD card when the value is 1 R/W
LW60411 Historical data Copy historical data between specific time range to U disk when the value is 1 R/W
LW60412 Historical data Copy historical data between specific time range to SD card when the value is 1 R/W
LW60413 Export start serial number of historical data R/W
LW60415 Export end serial number of historical data R/W
LW60417 Export start time of historical data Length: six characters; year, month, day, hour, minute and second R/W
LW60423 Export end time of historical data Length: six characters; year, month, day, hour, minute and second R/W
LW60429 File name of historical data exported to U disk and SD card Length: 24 characters R/W
LW60441 Cache region of password modification of User 1 Length: 16 characters; ASC display R/W
LW60449 Enable modify password of User 1 Modify the password of User 1 as that in cache region when the value is 1; reset automatically after setting R/W
LW60451 Cache region of password modification of User 2 Length: 16 characters; ASC display R/W
LW60459 Enable modify password of User 2 Modify the password of User 2 as that in cache region when the value is 1; reset automatically after setting R/W
LW60461 Cache region of password modification of User 3 Length: 16 characters; ASC display R/W
LW60469 Enable modify password of User 3 Modify the password of User 3 as that in cache region when the value is 1; reset automatically after setting R/W
LW60471 Cache region of password modification of User 4 Length: 16 characters; ASC display R/W
LW60479 Enable modify password of User 4 Modify the password of User 4 as that in cache region when the value is 1; reset automatically after setting R/W
LW60481 Cache region of password modification of User 5 Length: 16 characters; ASC display R/W
LW60489 Enable modify password of User 5 Modify the password of User 5 as that in cache region when the value is 1; reset automatically after setting R/W
LW60491 Cache region of password modification of User 6 Length: 16 characters; ASC display R/W
LW60499 Enable modify password of User 6 Modify the password of User 6 as that in cache region when the value is 1; reset automatically after setting R/W
LW60501 Cache region of password modification of User 7 Length: 16 characters; ASC display R/W
LW60509 Enable modify password of User 7 Modify the password of User 7 as that in cache region when the value is 1; reset automatically after setting R/W
LW60511 Cache region of password modification of User 8 Length: 16 characters; ASC display R/W
LW60519 Enable modify password of User 8 Modify the password of User 8 as that in cache region when the value is 1; reset automatically after setting R/W
LW60520 HMI Model 40 characters R
LW60540 Bootloader version number 40 characters R
LW60560 Operation system version number 40 characters R
LW60580 Software version number 40 characters R
LW60600 Enable operation record Enable record operation log when it is 1 R/W
LW60601 Number of operation record Display the current number of operation record R
LW60602 Enable screen shot Enable screen shot when it is 1; reset after setting R/W
LW60603 Storage location of screen shot 0-U disk; 1-SD card R/W
LW60604 Enable HMI protection Enable HMI protection when it is 1 R/W
LW60605 Set the level number of HMI protection password Set the level number of HMI protection password; up to 10 passwords can be set R/W
LW60606 – LW60835 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 1 password (password length is 16 characters); R/W
LW60629 -LW60651 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 2 password (password length is 16 characters); R/W
LW60652 -LW60674 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 3 password (password length is 16 characters); R/W
LW60675 -LW60697 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 4 password (password length is 16 characters); R/W
LW60698 -LW60720 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 5 password (password length is 16 characters); R/W
LW60721 -LW60743 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 6 password (password length is 16 characters); R/W
LW60744 -LW60766 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 7 password (password length is 16 characters); R/W
LW60767 -LW60789 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 8 password (password length is 16 characters); R/W
LW60790 -LW60812 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 9 password (password length is 16 characters); R/W
LW60813 -LW60835 Set period of validity of HMI protection is for year, month, day, hour, minute, second, deadline prompt and unlock password protection of Level 10 password (password length is 16 characters) R/W
LW60836 Enable save to HMI Preserve the HMI protection settings to HMI when it is 1; reset automatically after setting R/W
LW60837 Initialize HMI protection Set HMI protection to the initial state W
LW60997 Keyboard input or USB mouse operation Scanning machine input when the value is 1. Triggered when it is ON; reset automatically R/W
LW60998 End Symbol definition of USB bar code scanning End Symbol definition of USB bar code scanning. 0-ENTER,1-TAB+ENTER R/W
LW60999 Scan code length of USB bar code Scan code length of USB bar code R/W
LW61000 -LW61127 Storage usage of bar code scanning Storage usage of bar code scanning R/W
LW61128 Employed for printer parameters Employed for printer parameters R/W
LW61138 Source Formula/Recipe ID number of imported Formula/Recipe Source Formula/Recipe ID number of imported Formula/Recipe R/W
LW61139 Target Formula/Recipe ID number of imported Formula/Recipe Target Formula/Recipe ID number of imported Formula/Recipe R/W
LW61140 Clear Formula/Recipe ID number -1 when initial value is presented as a 16-Bit integer; otherwise, 65535 R/W
LW61141 Switch Formula/Recipe group number R/W
LW61143 Specific Formula/Recipe group number R/W
LW61216 LW61247 HMI serial number (S/N) information ASCII character display 32 lenght R
LW62020 – LW62039 Current Formula/Recipe name Displays the current formula/recipe name. Select «ASCII Display» control, check «Use Unicode», length 20. R